Guaraflex R

SELECTING AND SPECIFYING THE PRODUCT

 

Product Appraisal by BBA

The Guaraflex P product has received BBA (British Board of Agrément) Appraisal Number #00/3701 (BBA Logo)

 

Warranty

Warranties of up to 20 years on this system may be available, depending on the nature of the project, and strictly by negotiation only. Typical terms of warranty are provided in Section 12, please contact Sealtec for details applicable to your project.

 

NZBC Compliance

Test data examined by the BBA indicate that the product is stable at high temperatures and is flexible and resistant to impact damage at low temperatures.
Accelerated ageing tests indicate a satisfactory retention of properties.
Available evidence indicates that the product should have a life expectancy in excess of that of conventional grades of mastic asphalt used in car parking and HGV Service Deck situations.
With proper maintenance and repair, Guaraflex PP should perform satisfactorily for a period in excess of 20 years.

 

Ecological Statement

  • Guaraflex R is manufactured by Guaranteed Asphalt Ltd, a BS kite marked company and member of the UK Mastic Asphalt Council.
  • The Guaranteed Asphalt manufacturing plant at Corby is fully computerised and quality checked, and has attained a reputation as one of the most consistent mastic asphalt producers in the world today.
  • Guaranteed Asphalt has BS 5750 quality certification.
  • In January 2008, UK mastic asphalt became the first industry in the world to achieve the CarbonZero standard: see www.carbon100.com for more details.

 

1 General Design Considerations

General

Mastic Asphalt is the ultimate protection for a wide range of construction applications and offers total waterproofing integrity for roofing and tanking applications.

Whilst it is one of the worlds most traditional construction materials it has continued to develop with the times and even in todays fast-track building industry polymer modified mastic asphalt remains the unrivalled choice for many designers and specifiers.

It is installed by trained operatives who have undertaken the mastic asphalt industry’s extensive training programme which lasts for a minimum of three years to NVQ Level Two/Three, or equivalent. Polymer modified mastic asphalt can only be installed by approved contractors. In this way, the entire industry can offer comprehensive guarantees with complete confidence on both labour and materials.

This manual provides recommendations for the use of polymer modified mastic asphalt in roofing to both flat and sloping roofs and covers a variety of applications including roof gardens. A flat roof typically comprises ceiling, structural supports, roof deck, waterproof covering and surface protection and incorporates insulation and drainage. It may support ancillary items such as engineering equipment, hand railing and lightning conductors.

Polymer modified asphalt roofing requires the use of ancillary materials and products, most of which are covered by British Standards. Specifiers should satisfy themselves, by reference to manufacturers’ information and test results, that materials and products not covered by a British Standard will be suitable for their roofing requirements in particular situations and are compatible with the use of mastic asphalt. All such materials should be installed in accordance with manufacturer’s instructions.

For each roof the designer should first determine the form (pitched or flat) and the type (cold deck, warm deck or inverted) before selecting the appropriate deck materials, thermal insulation, and means of vapour control.

Design Of The Base

Substrates to which mastic asphalt is to be installed should be prepared to a true and even surface free from irregularities such as abrupt changes in levels, hollows, ridges or dips, therefore enabling the mastic asphalt to be applied to a reasonably uniform thickness.

All materials should provide a substantial and continuous support to the mastic asphalt application and should be able to sustain the loads imposed by traffic both during and after asphalting operations. The designer should study the need for movement joints in the structure. Movement joints should be continued at upstands, walls and perimeters of buildings.

Tolerances

Due to the nature of mastic asphalt, the nominal thicknesses given are indicative rather than precise. Any irregularities in the horizontal substrate will be reflected in the final surface with accompanying inconsistencies of thickness.

Damp-Proof courses

It is essential that a waterproofing membrane does not override a damp-proof course in vertical applications.

Ideally, damp-proof courses should be positioned one brick course above the chase into which mastic asphalt is applied, with the exposed course of brickwork normally being protected with a cover flashing extending 75mm down the face of the mastic skirting.

Where site restraints dictate that it is necessary to install a chase at the same level as the damp-proof course, there is a risk of damage occurring to the continuity of the damp-proof course, and special care is required during installation and cutting the chase.

 

Falls

Whilst ponding is not detrimental to the life of mastic asphalt it is generally desirable that falls are incorporated in flat roofs to assist in the discharge of rainwater and to minimise ponding.

All flat roof surfaces should be laid to cross falls and/or falls to ensure proper drainage as recommended in BS 6229:1982. Rainwater outlets should be sited at low points in the general roof area well clear of other penetrations, where possible.

Falls should normally be provided in the base on which the roof covering is to be laid. To ensure adequate drainage, allowance should be made for normal construction tolerances and deflections in order to achieve a minimum finished fall of 1:80. Particular attention should be paid to areas subject to pedestrian traffic such as access balconies or playing areas.

By choosing asphalt roofing adequate drainage is achieved by using a minimum finished fall of 1:80. It should be taken into account that other flat roofing materials usually require a minimum fall of 1:60 resulting in direct additional construction costs.

Drainage

Drainage should be provided and designed in accordance with the requirements of BS 6367:1983, Code of Practice for drainage of roofs and paved areas. Outlets should always be located at the level of the waterproof membrane and should be suitable for use in conjunction with mastic asphalt.

 

2 Substrates

Concrete

For in situ concrete or hollow block/pot constructions with an irregular surface, all falls except when provided as part of the structure should be formed by a screed such as given in BS 6229:1982. The surface should be provided with a float finish to a plane even surface free from ridges and indentations.

Precast Concrete Units

Precast concrete units should be used and fixed in accordance with manufacturer’s instructions and finished with a surface suitable to receive mastic asphalt.

Falls should be incorporated in the supporting structure or formed in a suitable screed.

Drying Out The Base

Concrete slabs and concrete decks cast in situ should be drained downwards through temporary drain holes formed in the low points of the roof deck. Subject to checking their effect on structural strength, the holes should be 25mm diameter, positioned to avoid reinforcement bars in the concrete in accordance with BS 6229:1982. The holes should not be filled until seepage and dampness has ceased, before finishing work on the ceiling is commenced. Precast concrete roof decking units with open joints are self-draining and holes are not required, but if the joints are subsequently to be sealed, they should be left open for as long as possible.

Sand & Cement Screeds

Where a reinforced concrete roof slab is overlaid with a screed to provide falls, such screed should be laid in accordance with BS 6229:1982. The surface should be provided with a float finish, even and smooth, free from hollows and ridges. The screed should be designed to remain free from cracks.

Lightweight Screeds

All lightweight screeds should be installed by contractors specialising in such work and laid strictly in accordance with manufacturer’s instructions to a smooth and even surface, free from hollows and ridges.

Asphalt Screeds

Asphalt screeds can be specified in the majority of cases falling to minimum thicknesses where traditional sand/cement and lightweight screeds require a minimum thickness of 50mm.

In addition to replacing a “wet trade’’ mastic asphalt screeds can be trafficked when cooled to ambient temperature and provide temporary waterproofing to enable internal trades to progress.

It should be noted that with an asphalt screed there is no need for a separate vapour control layer.

Note: Whilst the product is designed for vehicle traffic some indentations should be expected from long-standing point loads and deformation may result from situations of very high stress.

 


Timber Boarding

Roof decks of timber boarding should be designed in accordance with BS 6229:1982 and BS 5268:Part 2:1996.

The timber should be naturally durable or pretreated against infestation by wood boring insects and fungal decay as recommended in BS 5268:Part 5:1989. Any method of pre-treatment specified should be compatible with the use of bitumen-based products.

Boarding should not be less than 19mm nominal thickness, planed, closely clamped together with tongued and grooved joints or closely butted and secured by nailing with heads not protruding. Falls should be formed by firring or sloping the joists, in accordance with BS 6229:1982.

To avoid fungal attack of the timber boarded structures in cold roof constructions, ventilation should be provided within the roof void.

Adjacent to masonry walls, parapets and abutments, a free standing kerb should be securely fixed to the roof deck to allow for differential movement.

A free standing kerb is not required where a Guaraflash U & T flexible upstand detail is specified.

The timber base should be protected from rainwater during construction. Timber affected by dampness should be allowed to dry. Therefore, the fixing of ceilings should be delayed as necessary.

Plywood

Roof decks of plywood should be designed in accordance with BS 6229:1982 and BS 5268:1996. Falls should be formed by firring or sloping the joists.

The plywood should conform to the relevant requirement of BS 6566:Parts 1 to 8, should be specified as veneer plywood and should:

  • be WBP bonded in accordance with BS 6566:Part 8: 1985 (1991)
  • have a plywood durability of Class M of BS 6566:Part 7: 1985 (1991) or higher, or alternatively be preservative treated at least to the minimum requirement of BS 6566: Part 7: 1985 (1991). Any treatment should be compatible with bitumen over prolonged periods.

Note: It is not normally necessary to specify a plywood of appearance quality higher than Grade III of BS 6566: Part 6: 1985 (1991).

 


Woodwool Slabs

Roof decks of wood wool slabs should be formed from slabs conforming to Type SB of BS 1105:1981 (1994), not less than 50mm thick with a pre-screeded surface, fixed in accordance with the wood wool slab manufacturer’s instructions.

Pre-felted wood wool may be used to provide temporary weather protection and a vapour control layer in warm roof construction, and should be used in conjunction with a boarded insulant. Joints should be taped.

Where pre-screeded channel reinforced wood wool slabs are specified, the channel may form a thermal bridge unless protected on the outside by insulation. To reduce the risks of condensation, a warm roof system should be constructed by applying a suitable insulation over the wood wool slabs with a vapour control layer.

In cold roof constructions, ventilation should be provided within the roof void.

Profiled Metal Decking

Proprietary systems of troughed decks to be used in combination with mastic asphalt should be designed in accordance with BS 6229:1982.

The maximum permissible deflection as a multiple of span should be 1/325.

Metal decking does not provide a continuous supporting surface for mastic asphalt roofing, therefore the decking should be overlaid with a rigid board or sheet material secured to the crowns of the decking profile.

Adjacent to masonry walls, parapets, abutments and metal cladding, a free standing kerb should be securely fixed to the metal decking to allow for differential movement.

In certain circumstances a limited vapour control layer may be formed of felt conforming to BS 747:1994 or similar material. If higher degrees of vapour resistance are necessary, a two-layer or a fully supported vapour control layer should be installed.

 


Substrates For Inverted Roofs

Substrates for inverted roofs are usually designed to be constructed in concrete due to weight considerations. It is possible to lay over other substrates dependent on their ability to accommodate the imposed loadings.

Substrates For Warm Deck Roofs

Substrates in warm deck roofs will be formed by thermal insulation boards. Thermal insulation thickness and the risk of condensation build-up should be calculated. A vapour control layer should normally be incorporated.

 

3 Vapour Control

Control Of Water Vapour

Vapour control layers reduce the diffusion of moisture vapour into the thermal insulation element within a warm roof specification. Whilst water vapour diffusion is normally a slow process the need for effective vapour control becomes more necessary as levels of relative humidity increase within the building.

Any provision required to control interstitial condensation within the roof structure should be determined as recommended in BS 6229:1982 but with calculation method modified to conform to BS 5250:1989 (1995).

Laying Vapour Control Layers

Whenever a vapour control layer is specified the spreader should ensure its integrity, any damage being made good before the insulation boards are applied.

Particular care should be taken at all detail work to ensure the insulation is completely enclosed and protected against water vapour from below. Thermal insulation boards for use in warm roofs should be capable of resisting permanent deformation or damage when subjected to loads.

Laying Thermal Insulation Boards

Warm Roof Construction

Boards should be fully bedded to the vapour control layer normally in hot bitumen in a brick bond pattern and with edges firmly pushed together in accordance with the board manufacturer’s instructions.

The thermal insulation should be laid with a margin between the edges of the boards and all skirtings and abutments. The margin should be subsequently filled, prior to laying the first coat of horizontal mastic asphalt. This is not normally a requirement where insulated upstands are detailed.

Roof terraces or balconies subjected to static or pedestrian loads should be designed to accommodate the inverted roof system or consideration should be given to the incorporation of a suitable insulation such as cellular glass with a porous concrete tile finish to the membrane.

For information on insulation type/thickness to meet specific U value requirements please refer to Building Regulations 2001 (England and Wales) approved document L (Conservation of Fuel and Power).

N.B. The requirement for a separate vapour control layer is avoided where a warm roof specification using an asphalt screed or a protected membrane system is specified.

 

4 Separating/Isolating Membranes

Separating Membrane

The separating membrane should be one of the following and should be laid directly under the mastic asphalt:

  • Guarafelt CP/CP super
  • Guarafelt sheathing comprising a base of flax or jute, or other suitable fibres, impregnated with bitumen.
  • Guaraglass tissue.

Isolating Membrane

The isolating membrane to be laid over the mastic asphalt should be one of the following:

  • Waterproof building paper or Guarafelt CP where cementitious materials are to be laid onto mastic asphalt.
  • A non-woven polyester fleece, weight 130gm/m2 to 140gm/m2 where extruded polystyrene is to be laid onto mastic asphalt in the inverted roof construction.

Filter Membrane

A non-woven polyester fleece laid over extruded polystyrene insulation in inverted roof specifications when required by the insulation manufacturer.

 


INSTALLATION, DESIGN DETAILS AND CARING FOR THE PRODUCT

5 Installation Requirements

Click here to find Current Licensed Applicators.

Guaraflex R System

Installation

 

The system is laid using the techniques for mastic asphalt described in the relevant clauses of BS 8218:1998, manufacturers current product literature and or written technical specifications which may vary from standard given site constraints.

General

The number of coats should be appropriate to the waterproofing requirements and traffic conditions of the roof. When laid to falls of 1:80 or greater Guaraflex PR roofing is laid in two coats to a thickness of 20mm, in accordance with BS 8218:1998.

Where falls are less than 1:80 or a ‘buried’ specification is required, three layers of Guaraflex PR to a total thickness of 30mm should be applied.

Horizontal, Sloping And Vertical Surfaces

Horizontal Surfaces Up To And Including 10° Pitch

On horizontal surfaces up to and including 10° pitch the Guaraflex PR should be laid in two coats to a thickness of 20mm on Guaraflex sheathing membrane.

In general, difficulties can be experienced in laying asphalt directly over insulants to surfaces over 5° pitch.

Sloping And Vertical Surfaces Over 10° Pitch, Other Than Timber Or Lightweight Concrete And Excluding Skirtings

On sloping and vertical surfaces over 10° pitch the Guaraflex PR should be laid in three coats to a thickness of 20mm without a separating membrane.

Sloping and vertical surfaces of timber or lightweight concrete over 10° pitch, including skirtings.

On sloping and vertical surfaces of timber or lightweight concrete Guaraflex PR should be laid in three coats to a thickness of 20mm on expanded metal lathing over a separating membrane of Guarafelt sheathing.

Horizontal Surfaces Designed As Roof Gardens Or Buried Waterproofing

On horizontal surfaces designed as a roof garden or as a buried waterproofing membrane, the Guaraflex PR should be laid in three coats to a thickness of 30mm over a separating membrane of Guarafelt CP or Guaraglass tissue.

 


Skirtings To Brickwork And Concrete

Skirtings should be tucked into a chase or groove at the top edge, and should be a minimum 150mm above all roof finishes. Normally skirtings would be applied in two coats to a thickness of 13mm.

Skirtings over 300mm are regarded as vertical work and should be applied in three coats to a thickness of 20mm.

On old or irregular brickwork or blockwork it is usually necessary for the skirtings to be applied in three coats, the first coat being a ‘dubbing out’ coat to correct irregularities in the wall followed by the standard two coat work. The total thickness should be between 15mm and 20mm. Cement and sand render can be used as an alternative for ‘dubbing out’ to correct irregularities. Particular care should be taken to ensure proper adhesion of the first coat of mastic asphalt. The exposed uppermost part of the mastic asphalt skirting should be formed with a splay to shed rainwater, even though a metal flashing may be fixed to cover the exposed part. A splayed arris is formed when mastic asphalt is continued through the wall to form a horizontal damp-proof course.

Alternatively flexible upstands may be more suitable and can be specified with the Guaraflex R Waterproofing System - See Section 6 - Roofing Details

Fillets

Fillets should be formed with a solid angle of Guaraflex PR, in two coats, with a minimum of 40mm on the face, at approximately 45°.

Chases

Chases should be provided in brickwork and concrete and should be 25mm x 25mm. The lower nib of the chase should be carefully removed in order to maintain a full thickness of Guaraflex PR at this point. The chase should be pointed as soon as practical afterwards using a sand cement mortar containing a suitable polymer admixture such as styrene butadiene rubber or acrylic.

Margin Infill

In a warm roof construction a minimum 25mm margin would normally be created between the edges of the thermal insulation boards and the skirting/upstands. The margin should be solidly filled to provide support to the skirting and angle fillet, and to eliminate voids at these junctions. With the majority of thermal insulation materials, the margin should be infilled with mastic asphalt, however, where temperature susceptible materials are used, an earth damp sand cement mix should be used.

An infill is not normally required where an insulated and/or Guaraflash U&T flexible upstand detail is specified.

 


Verges

Edge Trims

Suitable preformed roof edge trims may be applied at edges of roofs, using a section designed for use with mastic asphalt. Materials adversely affected by thermal movement should be avoided.

Keying To Timber Surfaces

To provide an adequate key for Guaraflex PR laid on vertical timber surfaces and those of slope greater than 10°, and also at junctions formed with such surfaces, a continuous layer of metal lathing should be securely fixed by means of nails or staples. The expanded metal lathing should be fixed over Guarafelt sheathing at maximum 150mm centres in all directions.

Keying To Metal Surfaces

All metal surfaces such as pipes, metal standards etc. should be treated with high-bond primer in accordance with the manufacturer’s instructions. Alternatively, expanded metal lathing, strapped or spot welded, may be used to provide the necessary key.

Where pipes penetrate timber, metal or wood wool roof decks, or where pipes carry hot materials or require to be isolated, an appropriate sleeve should be provided in order to isolate the mastic asphalt from the pipe, alternatively flexible upstands may be more suitable and can be specified with the Guaraflex R Waterproofing System - See Section 6 - Roofing Details.

Treatments for vertical and sloping surfaces to receive mastic asphalt

 

Treatment
Guarafelt Sheathing
Bitumen Coated Expanded Metal Lathing
High-bond Primer
Mechanically Prepared Surface
1
2
3
4

 

Surface Treatment Required
Facing Bricks (Flush Pointed)
Engineering Bricks (Flush Pointed)
Timber
Smooth Concrete (Alternative 1)
Smooth Concrete (Alternative 2)
Textured Concrete (Coarse Aggregate)
Lightweight Aggregate Concrete
Lightweight Aggregate Brickwork
Metal Pipes and the like (Alternative 1)
Metal Pipes and the like (Alternative 2)
3
3 and 2
1 and 2
4 and 3
3 and 2
3
1 and 2
1 and 2
3
3 and 2

 

6 Roofing Details

Click here to download Guaraflex Drawing Set (AutoCAD dwg only)

Click any of the thumbnail images below to view an enlarged illustration.

1: Concrete roof deck and skirting (cold roof)
1a: roof deck with free-standing kerb (cold roof)
1b: Private balconies with tiles (bitumen bedded)
1c: Private balconies with tiles (cement mortar bedded)
2: Concrete deck and skirting
3: Proprietary System 2R - Concrete Deck
4: Private balconies with tiles (bitumen bedded)
5: Proprietary System 3R - Timber Deck
6: Metal Deck with free standing kerb
7: Proprietary System 4R - Metal Deck
8: Traditional asphalt detail concrete deck
9: Proprietary System 2R(1) – Concrete deck
10: Traditional asphalt detail timber/metal deck
11: Proprietary System 3R(1) – Timber deck
12: Proprietary System 4R(1) metal deck

 

Undercut Drip

A mastic asphalt apron with an undercut drip may be provided on masonry constructions, the mastic asphalt being applied in two coats to a thickness of 13mm.

Eaves Gutters

Where the roof falls into an eaves gutter, the asphalt would normally be finished over a lead or other suitable flashing set into a rebate in the substructure. The flashings should be welted at the back and the depth of rebate should allow for the full thickness of mastic asphalt to be maintained over the welt. Pre-formed edge trims would not normally be used at this detail, unless specifically designed ie. watershed type.

A lead detail should be designed and installed in accordance with The Lead Sheet Manual, Volume 1, Lead Sheet Flashings.

13: Concrete roof eaves gutter (warm roof)
14: Apron and drip to concrete (optional water check)
15: Timber roof eaves gutter (warm roof)

 

Rainwater Outlets

Rainwater Outlets should be no higher than the immediate surrounding finish and be mechanically secured to prevent movement. Adequate provision should be made for surface water run-off before the waterproof membrane is completed.

 

The type of outlet used should be suitable for use in conjunction with mastic asphalt. Usually spun aluminium or cast iron outlets with an internal clamping ring are to be preferred.

16: Clamping Cone Outlet

 

Movement Joints

It is normally only necessary to provide movement joints in a mastic asphalt roof membrane where one is provided in the structure. Any movement joints should always be located at the high point of the falls.

Where it is considered necessary to provide movement joints in the roof structure, these should be of the twin kerb type with a suitable metal or butyl rubber capping.

 

Flush movement joints in mastic asphalt should be avoided where possible. Where they are unavoidable, care should be taken to ensure that a secure bond can be made between the joint and the roof covering.

17: Concrete upstand expansion joint (warm roof)
18: Sleeved pipe passing through roof (warm roof)

 

Inverted Roofing System

Extruded polystyrene is used as the insulation within these systems laid loose on a geotextile isolating membrane weighted by either ballast or paving slabs which protect the insulation from UV degradation and prevent flotation in the inverted roofing system.

 

Lightweight systems are available which use a modified cementitous topping bonded to the extruded board and provide a substantial saving on the imposed loading of the conventional application. The suitability of this method for specific applications should be verified by the insulation manufacturer.

19: Concrete roof deck and skirting (traditional inverted roof) with external insulant
20: Proprietary System 1 Standard inverted insulated roof/patio
21: Proprietary System 2 Super inverted insulated roof/patio
22: Waterproofing to roof garden (partly insulated)
23: Waterproofing to roof garden (fully insulated)

 

7 Product Data

Fire

Because of its high mineral content, mastic asphalt is virtually incombustible. Indicative tests have been performed on samples of insulated mastic asphalt roof decks in accordance with the procedures specified in (draft) European Standard prEN 1187-1 and prEN 1187-2. No significant flame spread was observed and no flame penetration occurred in either test. Mastic asphalt fulfils all the external fire resistance required for a roof covering and achieved the highest rating (p60) when tested as described in BS 476: part 3:1975.

Thermal Conductivity

Mastic Asphalt has a thermal conductivity, (Lambda) value, of between 0.43 W/m K and 1.15 W/m K.

A (lambda) value of 0.50 W/m K may be assumed for design purposes.

Thermal Expansion

Mastic Asphalt is thermoplastic and is capable of accommodating normal movements encountered in well-designed building structures.

Coefficient Of Cubic Expansion

The coefficient of cubic expansion is 15 x 10-5/ ºC.

Toxicity

Mastic Asphalt is non-toxic and is generally suitable for use in contact with potable water.

Odour

Mastic Asphalt is odourless after laying.

Mass

The mass of mastic asphalt varies due to a number of factors such as the differing proportions of constituents utilised in its manufacture and the nature and quality of coarse aggregate incorporated. For practical and load calculation purposes, however, the mass can be taken to be 2.4kg/m² per mm of thickness.

Control Of Water Vapour

The vapour resistivity of mastic asphalt can be assumed to be not less than 100 000 MN s/ (gm). For condensation control calculations a factor of 20,000 MNs/ (gm) may be taken (i.e. the ratio of the vapour resistivity of the material to that of still air) see also BS 6229:1982.

Resistance To Water

Mastic asphalt is impervious to water.

Resistance To Biological Attack

Mastic asphalt is vermin-proof and rot-proof.

Compressive Strength

When mastic asphalt is fully confined it has the same compressive strength as the containing material. When not confined, the compressive strength is dependent upon a number of factors including the temperature to which it may be subjected. Advice on individual cases should be sought from Sealtec.

Durability

'Asphalt roofing properly designed and laid should prove capable of lasting 50-60 years' BRE Digest 144 Asphalt and built-up felt roofings: Durability.

Recycling

Mastic Asphalt can be recycled.

Surface Protection - General

All asphalt roofing, including upstands, should be protected against static point loading and mechanical damage.

On inverted roofs, the ballast and insulation will provide protection to the mastic asphalt.

The insulation and ballasting should be installed immediately on completion of the laying of the mastic asphalt or as soon as is practically possible. Care should be taken to provide adequate protection at upstands.

Sand Rubbing

On horizontal and slightly sloping surfaces, immediately after completion of laying and whilst the mastic asphalt is still warm, clean sharp sand should be rubbed evenly into the surface of the mastic asphalt with a wooden float prior to application of the solar reflective coating.

Solar Relective Paint

Solar reflective paint should be free from materials deleterious to mastic asphalt i.e. metallic pigments, non- compatible solvents or water based emulsions.

Chemical And Oil-Resisting Protective Paint

A purpose-made coloured and protective coating based on a synthetic resin in solution with industrial ethanol which does not attack/abuse mastic asphalt surfaces. Further advice on solar reflective treatments can be obtained from Sealtec.

 

8 Maintenance And Repair

General

Guaraflex roofing which has been installed in accordance with the recommendations of this technical guide and the relevant British Standard Code of Practice can be expected to provide trouble-free service provided it is properly maintained.

Maintenance inspections should be carried out regularly by persons knowledgeable in mastic asphalt work.

All flat roofs should be inspected annually, preferably in the autumn, to clear leaves, debris and dirt, which may prevent proper drainage or cause deterioration. Where the roof is in an area of high dust or pollution, or in close proximity to trees, more frequent inspections may be necessary.

 

Inspection should be carried out both internally and externally. Particular attention should be given externally to roof covering abutments, joints, gutters and outlets and internally to corners, abutments and penetrations.

Observations by occupants of building should be noted. For situations not covered by the above please contact Sealtec on 0800 179 000.

 

9 Disclaimer

This information is intended solely as a guide and to provide general design advice concerning the use of Sealtec products and systems in typical applications.

Before using any product or system, checks should be made to ensure that the product / system are suitable for use in the specific application

This information does not contain the full details required for construction, nor does it constitute an express statement as to fitness for a particular purpose, professional advice is required to take into account all site specific influences.

All technical detail drawings provided in this document remain the property of Sealtec Ltd and cannot be altered without the express consent of Sealtec Ltd. Sealtec Ltd accept no responsibility and makes no warranty regarding the use of this information with non-Sealtec products.

Sealtec Ltd reserves the right to alter or update information parameters and formulations at any time without prior notice.

 

10 New Zealand Distributor

SEALTEC LTD
P.O Box 101431, North Shore City
48 Diana Drive, Glenfield
Freephone: (0800) 179 000
Phone: (09) 444 9047
Fax: (09) 444 9049
Email: This e-mail address is being protected from spambots. You need JavaScript enabled to view it

 

11 Component Manufacturer

GUARANTEED ASPHALT LTD
Earlstree Industrial Estate
Princewood Road
Corby
Northants NN17 4AP
United Kingdom
Phone: +44 1536 260995
Fax: +44 1536 262381
Email: This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Web: guaranteedasphalt.com

 

12 Typical Terms of Warranty

The exact duration and terms of available warranty may depend on many variables in a given project.

Please contact Sealtec for details applicable to your specific project.

Sealtec Ltd – Guaraflex R Mastic Asphalt Roof Waterproofing System Warranty

Warranty: Sealtec Limited ("Sealtec") warrants for a period of 15 years from the date of purchase that it's Guaraflex R Mastic Asphalt Roof Waterproofing System and Sealtec accessories (The 'Products'), will be free from production defects, and subject to compliance with the conditions below, and conditions as set out in individual Manufacturers and Sealtec Limited’s product literature current at the time of installation. The Guaraflex R Mastic Asphalt Roof Waterproofing System Technical Manual sets out the approved and recommended methods for mastic asphalt installation. A copy of the Guaraflex R Mastic Asphalt Roof Waterproofing System Technical Manual is available from Sealtec Ltd.

Conditions of Warranty; The warranty is strictly subject to the following conditions:

(a)    The Products must be installed by a competent Sealtec Licensed Applicator, strictly in accordance with the Guaraflex R Mastic Asphalt Roof Waterproofing System Technical Manual current at the time of installation, utilizing Sealtec components or products specified in the Guaraflex R Mastic Asphalt Roof Waterproofing System Technical Manual. Where the Guaraflex R Mastic Asphalt Roof Waterproofing System Technical Manual does not provide a suitable detail for installation of The Products then installation must be in accordance with best trade practice determined in consultation with the Territorial Authority and designer of the building works. Further, all other products, including coating systems, applied to or used in conjunction with The Products must be applied or installed strictly in accordance with the relevant manufacturer's instructions and best trade practice.
(b)    Sealtec Ltd. will not be liable under this warranty unless a written claim is notified to Sealtec Ltd. within 30 days of the defect becoming reasonably apparent.
(c)    This warranty is for the benefit of the original owner of the building where the Guaraflex R Mastic Asphalt Roof Waterproofing System has been installed. This warranty is not transferable to subsequent owners of the building.
(d)    The Products must be maintained strictly in accordance with the Guaraflex R Mastic Asphalt Roof Waterproofing System Technical Manual. Further, all other products, including coating and jointing systems, applied to or used in conjunction with The Products must be maintained strictly in accordance with the relevant manufacturer's instructions and best trade practice.
(e)    The building works in which The Product has been incorporated must be designed and constructed in strict compliance with all relevant provisions of the current New Zealand Building Code ("NZBC"), regulations and standards, and the Building Consent relating to the building works.
(f)    The customer's sole remedy under this warranty is (at Sealtec Ltd.'s option) that Sealtec Ltd. will either supply replacement Products, rectify the affected Products or pay for the cost of the replacement or rectification of the affected Products.
(g)    Sealtec Ltd. will not be liable for any losses or damages (whether direct or indirect) including property damage, personal injury, consequential loss, economic loss or loss of profits, arising in contract or negligence or howsoever arising. Without limiting the foregoing Sealtec Ltd. will not be liable for any claims, damages or defects arising from or in any way attributable to poor workmanship, poor design or detailing, settlement or structural movement and/or movement of materials to which The Products are attached, incorrect design off the structure, acts of God including but not limited to earthquakes, cyclones, floods or other severe weather conditions or unusual climatic conditions, efflorescence or performance of paint/coatings applied to The Products, normal wear and tear, growth of mould, mildew, fungi, bacteria, or any organism on the surface of any Products (whether on the exposed or unexposed surfaces).
(h)    All warranties, conditions, liabilities and obligations other than those specified in this warranty are excluded to the fullest extent permitted by law. This warranty does not exclude or modify any legal rights a customer may have under the Consumer Guarantees Act 1993. Unless otherwise specified in writing at the time of sale, Sealtec Ltd. assumes no liability for The Products being fit for any particular purpose under the Building Act 2004, other legislation or at common law.
(i)    If any remedial work undertaken under this warranty involves re-coating of The Products, the customer acknowledges and agrees that there may be slight colour differences between the original and replacement Products due to the effects of weathering and variations in materials overtime.